Answers are grounded in this paper and cite their sources.
Assessment of CO2 booster systems shows significant energy savings and lower environmental impact in tropical climates, indicating viable alternatives to high-GWP refrigerants.
• CO 2 booster and cascade systems assessed across tropical and subtropical climates. • First CO 2 refrigeration assessment covering four major Colombian cities. • BS-E excels in cool-moderate climates; BS-C-E performs best in hot regions. • BS-E and BS-C-E minimise TEWI; R404A shows the highest impact. • System suitability varies strongly with climate, shaping efficiency and emissions. This study presents the energy, exergy, and environmental performance evaluation of five CO 2 -based refrigeration configurations, namely a conventional booster (BS), booster with parallel compression (BS-PC), booster with ejector (BS-E), NH 3 /CO 2 cascade booster (BS-C), and ejector-assisted cascade booster (BS-C-E), together with the conventional R404A systems, under high-altitude, tropical, and hot-humid climatic conditions representative of four major Colombian cities (Bogotá, Medellín, Cali, and Barranquilla). Results show that for ambient temperatures below 26 °C, ejector-assisted booster systems deliver the highest efficiency, with the lowest annual energy consumption in Bogotá, Medellín, and Cali (411636 kWh/year, 442,218 kWh/year, and 486,673 kWh/year, respectively), corresponding to energy savings of approximately 6.8–10.2% relative to the BS. At higher ambient temperatures, hot-humid climates, such as Barranquilla, the BS-C-E configuration provided the lowest energy consumption (492852 kWh/year), achieving up to 12.7% annual energy savings compared with BS. Exergy analysis reveals that gas coolers dominate irreversibilities in booster systems, whereas cascade configurations exhibit a more balanced exergy destruction distribution. Environmental assessment based on highlights a critical energy–environment trade-off. Although the R404A reference system shows lower energy consumption, the direct TEWI associated with R404A remains more than three orders of magnitude higher than that of the CO 2 -based systems, whereas for all CO 2 configurations direct emissions remain negligible and total TEWI is governed almost entirely by indirect emissions related to electricity consumption. Results show that climate-specific system selection is essential, balancing efficiency gains against system complexity, and environmental impact, and strongly supports the transition away from high-GWP refrigerants toward CO 2 -based technologies.
No takes yet. Share an insight, caveat, or question.
Amaris et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: