Numerical analysis investigates load-bearing capacity in slender columns using high-strength materials, implying design guideline enhancements.
While high-strength materials are widely used in engineering practice, especially for those applications where a superior axial compression capacity is needed – as it is the case of concrete encased steel (CES) composite columns –, most studies still focus on normal-strength materials or consider only partially encased sections. Research on the mechanical behaviour of high-strength concrete fully encased high-strength steel composite columns remains limited. To address this gap, this study numerically investigates their load-bearing performance, focusing on slender columns. While the confinement effect provided by the steel profile and stirrups on concrete has been addressed in previous studies, the related mechanisms have not yet been fully reflected in numerical simulations. This study incorporates the most suitable existing models in a unified way to effectively capture the confinement effect in the finite element model and validates it through experimental data. The accuracy of the numerical model is demonstrated by comparing the load-displacement responses with the experimental results. Based on the validated numerical model, parametric studies comprising a total of 342 analysis cases are conducted to systematically investigate the influence of material strengths, geometrical dimensions, eccentricity and relative slenderness on the load-bearing capacity of CES composite columns. Furthermore, a detailed methodology is presented for calculating the axial capacity of concentrically and eccentrically loaded CES composite columns. The applicability of the calculation method in EN1994-1-1 for predicting the load-bearing capacity of high-strength CES composite columns is evaluated based on the numerical results. Targeted design recommendations are proposed accordingly, aiming to extend the applicability range of the current design provisions to cover those cases involving high-strength materials. • A FE model was developed for slender CES columns including the confinement effect. • A database of 45 tests on slender CES columns was established and validated. • Detailed presentation of EN 1994-1-1 calculation methods for CES columns. • Evaluation and recommendations for EN 1994-1-1 calculation methods for CES columns.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: