This study introduces SwinPix, a novel network architecture designed to explore the effectiveness of multi-level low-dose (LD) PET inputs as prior knowledge for standard-dose (SD) PET image prediction. By employing SwinPix architecture, we assess the performance of single-input and multi-input models trained with PET data at 4%, 6%, and 10% dose levels. Two models were developed: the first was trained using a single input corresponding to 4%, 6%, and 10% LD PET images, while the second considered a multi-input approach, utilizing three lower-dose inputs to predict the corresponding SD PET images. The performance of the six models was evaluated using structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), mean standardized uptake value (SUVmean) bias, SUVmax bias, and root mean square error (RMSE) within the entire head region and malignant lesions. The SwinPix multi-input model outperformed single-input versions across all dose levels. At 4%, PSNR increased by 13%, SSIM improved from 0.97 to 0.99, while RMSE (lesion/head) dropped by 82-86%. Similarly, SUVmean and SUVmax biases decreased by 78% and 58%, respectively. At 6% and 10% dose levels, SwinPix showed comparable improvements, reducing RMSE by over 40% and SUV biases by up to 53%. Compared to Pix2Pix and Swin Transformer, SwinPix consistently achieved the best reconstruction quality. All improvements were statistically significant (p < 0.01), supporting the effectiveness of multi-input SwinPix for accurate LD PET imaging. SwinPix offers a hybrid transformer-based solution for LD PET reconstruction. By incorporating multi-level LD PET inputs through a Generative adversarial network (GAN) framework, it enhances image quality and lesion quantification while maintaining computational efficiency, supporting its potential for clinical deployment.
Azimi et al. (Mon,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: