PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 13, 2026AIP Advances1 citationsOpen Access

Advanced graphene–MXene–black phosphorus multilayered metasurface sensor for high-sensitivity terahertz brain tumor detection

View Full Paper
JWJacob WekalaoHEHussein A. ElsayedHAHaifa A. Alqhtani

Key Points

  • This research aims to develop a highly sensitive metasurface sensor for detecting brain tumor biomarkers in liquid biopsies.
  • Design of a multilayered metasurface integrating graphene, MXene, and black phosphorus.
  • Systematic optimization via numerical simulations using COMSOL Multiphysics.
  • Integration of machine learning models for performance prediction.
  • Performance analysis across various refractive indices and geometric modifications.
  • Achieved sensitivity of 2308 GHz/RIU across a refractive index range of 1.3333–1.4833.
  • Identified an optimal sensing regime at RI = 1.3425 with a figure of merit of 20.79 RIU−1.
  • Detection limit as low as 0.079 RI.
  • Predictive accuracy of 85%–100% using random forest regression models.

Abstract

In this research, we present a multilayer metasurface sensor design integrating graphene, MXene, black phosphorus, and gold for the ultrasensitive detection of brain tumor biomarkers in liquid biopsy samples. The hierarchical structure consists of a MXene-coated rectangular resonator, a black phosphorus-coated square resonator, a gold-coated circular ring, and a graphene-based circular substrate. This architecture was systematically optimized through comprehensive numerical simulations using COMSOL Multiphysics 6.3, integrated with machine learning frameworks. The proposed sensor demonstrates an outstanding sensitivity of 2308 GHz/RIU across a physiologically relevant refractive index range (1.3333–1.4833), significantly outperforming current state-of-the-art devices. Performance analysis identifies an optimal sensing regime at RI = 1.3425, achieving a figure of merit of 20.79 RIU−1 and a detection limit as low as 0.079 RIU. Detailed investigations of the transmission spectra under varying graphene chemical potentials (0.1–0.9 eV), incident angles (0°–80°), and geometric modifications of the resonators reveal highly tunable sensing behavior. Furthermore, Random Forest Regression models achieve predictive accuracies of 85%–100%, enabling reliable estimation of sensor performance across diverse operating conditions. Collectively, these results establish a solid foundation for employing advanced 2D material–based metasurfaces in minimally invasive and early-stage brain tumor diagnostics, thereby advancing the capabilities of next-generation liquid biopsy technologies.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wekalao et al. (2026) studied this question.

synapsesocial.com/papers/69b3ab3c02a1e69014ccbe24https://doi.org/10.1063/5.0305214
Ask AI
Helpful
Bookmark
Share
View Full Paper