Efficacy of a Prototype Inspiratory-Synchronized Small Particle vs Conventional Vibrating Mesh Nebulizer During Pediatric and Neonatal Mechanical Ventilation

View Full Paper
Ask AI
Bookmark
Share

Authors

PKPaul KarabelasCSCaylie A. SheridanJFJames Fink

Discussion

Loading...

Member takes

Overview

Comparison of aerosol delivery from small particle nebulizer and standard nebulizer during neonatal and pediatric mechanical ventilation, indicating better inhaled doses with specific placements.

Key Points

  • The study aimed to compare aerosol delivery efficiency of a small particle nebulizer with a conventional nebulizer during mechanical ventilation in neonates and pediatrics.
  • Used a critical care ventilator with heated circuit for pediatric and neonatal settings.
  • Set parameters for volume control and various breath settings for both populations.
  • Administered albuterol with two types of nebulizers and assessed inhalation dose using a collecting filter and UV spectrophotometry.
  • iVMN provided higher inhaled doses than conventional nebulizer in both neonatal and pediatric ventilation settings.
  • In neonatal ventilation, the placement of the nebulizer significantly affected the dose delivered.
  • In pediatric ventilation, optimal aerosol delivery was achieved with specific nebulizer placements.

Cite This Study

Karabelas et al. (2023) studied this question.

synapsesocial.com/papers/69b4adb518185d8a39801903https://doi.org/10.4187/respcare.20233951419
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1In Vitro Comparison of Inspiration Synchronized and Continuous Vibrating Mesh Nebulizer During Invasive Mechanical Ventilation2022
  2. 2Vibrating Mesh and Jet Nebulizer Performance in Pediatric Respiratory Support: A Multi-Modality In Vitro Comparison2026
  3. 3In Vitro Comparison of Inspiration Synchronized and Continuous Vibrating Mesh Nebulizer During Noninvasive Ventilation With a Single Limb Circuit2022
  4. 4In Vitro Comparison of Inspiration Synchronized and Continuous Vibrating Mesh Nebulizer During Noninvasive Ventilation With a Dual Limb Circuit2022
  5. 5Aerosol Delivery With a Vibrating Mesh Nebulizer Across Tidal Volume-Based Pediatric Invasive Ventilation Models: An In Vitro Evaluation2026