Evaluation reveals high accuracy in detecting color vision defects using the Standard Pseudoisochromatic Plate test, showing clinical reliability.
The Standard pseudoisochromatic Plate (SPP) test was administered to 346 normals, 55 anomalous trichromats, and 46 dichromats. Its ability to detect and classify congenital color defectives was assessed. The performance of each plate was assessed separately and compared with its colorimetric properties. The test as a whole achieves a high level of accuracy in separating normals from color vision defectives [Youden's Index (YI) = 92.4%] and a high reliability (71.3%) in classification of the congenital color vision defectives. The performance of individual plates in separating color normals and color vision defectives of individual plates varies (YI ranges from 69.8 to 86.1%). A set of three plates can be chosen, which achieves a performance similar to that of the whole test. The test is found to be a reliable clinical screening method for congenital red‐green color vision defectives.