Demonstrates lid retraction affects corneal astigmatism in different astigmatic populations, suggesting pressure factors play a role.
Corneal toricity was measured using a keratometer with the lids in the normal position, and with the lids retracted. Lid retraction usually changed the measured toricity. In corneas with more than 1.00 D of with‐the‐rule astigmatism, the change was in the direction of less with‐the‐rule astigmatism. In corneas with astigmatism between 1 D with‐the‐rule and 1 D against‐the‐rule, the change was not systematic. The results compare with the original experiment of Masci (1965), who also found that corneas with more with‐the‐rule toricity show a greater reduction in toricity when the lids are retracted. Clearly the pressure the lids exert on the eyeball is a major factor influencing astigmatism.
No takes yet. Share an insight, caveat, or question.
Wilson et al. (1982) studied this question.