Key result
99mTc-HMDP scintigraphy provides comparable excellent diagnostic accuracy to 99mTc-PYP for ATTR-CA.
Why the study?
Bone-avid tracers 99mTc-PYP and 99mTc-HMDP facilitate the noninvasive diagnosis of ATTR-CA, but direct comparison of these two methods was needed.
Does 99mTc-HMDP scintigraphy provide comparable diagnostic accuracy and uptake patterns to 99mTc-PYP scintigraphy in patients with suspected cardiac amyloidosis?
Observational (n=83)
No
Does 99mTc-HMDP scintigraphy provide comparable diagnostic accuracy and uptake patterns to 99mTc-PYP scintigraphy in patients with suspected cardiac amyloidosis?
99mTc-HMDP and 99mTc-PYP scintigraphy provide comparable diagnostic accuracy and regional uptake patterns for transthyretin cardiac amyloidosis, supporting their clinical interchangeability when standardized protocols are used.
Answers are grounded in this paper and cite their sources.
Supports clinical interchangeability of 99mTc-HMDP and 99mTc-PYP with standardized protocols; extends imaging flexibility for transthyretin cardiac amyloidosis.
Background Bone-avid tracers, such as 99m Tc-pyrophosphate (PYP) and 99m Tc-hydroxymethylene diphosphonate (HMDP), facilitate the noninvasive diagnosis of transthyretin cardiac amyloidosis (ATTR-CA). In this study, we compared these two methods. Methods We retrospectively reviewed 83 patients with suspected or diagnosed cardiac amyloidosis (mean age, 79 years; 11 women) who underwent PYP and HMDP scintigraphy. Early (1 h) imaging was available for of 72/50 patients with PYP/HMDP, and all patients underwent delayed (3 h) imaging. Visual grading (Dorbala score), heart-to-contralateral lung (H/CL) ratios, and relative segmental uptake (RSU) derived from SPECT (3 h) polar map analysis using the quantitative perfusion SPECT software were compared. Results visual scores showed substantial agreement. The H/CL ratio showed a strong correlation. Bland–Altman analysis revealed fixed and proportional biases, with discrepancies increasing at higher uptake levels. The median H/CL values were comparable at 1 h, whereas HMDP showed slightly higher delayed values. Receiver operating characteristic analysis indicated excellent and good diagnostic accuracy at 1 and 3 h, respectively. Using routine diagnostic criteria, SPECT visual assessment demonstrated comparable diagnostic performance between PYP and HMDP. RSU analysis in 34 patients demonstrated similar segmental uptake distributions for both tracers, with basal and septal predominance, consistent with the apical-sparing patterns described previously. Conclusions PYP and HMDP demonstrated comparable diagnostic accuracies for ATTR-CA. PYP has been extensively validated and is suitable for early imaging, whereas HMDP has a slightly higher delayed uptake and lower blood pool activity. When interpreted using routine diagnostic criteria, SPECT provided equivalent diagnostic performance for PYP and HMDP. Segmental analyses confirmed the preservation of the characteristic apical sparing across the tracers. Both tracers are clinically interchangeable when standardized acquisition and interpretation protocols are applied.
No takes yet. Share an insight, caveat, or question.
Ensako et al. (2026) conducted an observational in Cardiac amyloidosis (n=83). 99mTc-PYP scintigraphy vs. 99mTc-HMDP scintigraphy was evaluated on Diagnostic accuracy (AUC) for ATTR-CA at 1 hour (p=0.865). 99mTc-PYP and 99mTc-HMDP scintigraphy demonstrated comparable and excellent diagnostic accuracy for transthyretin cardiac amyloidosis, with 1-hour AUCs of 0.919 and 0.915, respectively.
Synapse has enriched 10 related papers. Consider them for comparative context: