Key result
The 1-hour heart-to-contralateral lung (H/CL) ratio on semi-quantitative 99mTc-PYP planar scintigraphy demonstrated excellent diagnostic accuracy for identifying ATTR-CA with an AUC of 0.97.
Why the study?
The diagnostic contribution of semi-quantitative uptake indices and extracardiac tracer distribution in 99mTc-PYP planar scintigraphy for transthyretin cardiac amyloidosis remained incompletely defined.
Does semi-quantitative planar 99mTc-PYP scintigraphy accurately diagnose ATTR cardiac amyloidosis in patients with suspected disease?
Cohort (n=174)
No
Does semi-quantitative planar 99mTc-PYP scintigraphy accurately diagnose ATTR cardiac amyloidosis in patients with suspected disease?
Effect estimate: AUC 0.97
p-value: p=<0.001
Semi-quantitative 99mTc-PYP planar scintigraphy, specifically the 1-hour H/CL ratio, provides high diagnostic accuracy for ATTR cardiac amyloidosis.
Allows confident non-invasive ATTR-CA diagnosis in suspected patients; reinforces value of semi-quantitative planar 99mTc-PYP scintigraphy.
Technetium-99m-pyrophosphate (99mTc-PYP) planar scintigraphy, a core modality of cardiac amyloid radionuclide imaging (CARI), is a widely established noninvasive technique for diagnosing transthyretin cardiac amyloidosis (ATTR-CA). However, the diagnostic contribution of semi-quantitative uptake indices and extracardiac tracer distribution remains incompletely defined. To evaluate the diagnostic performance of semi-quantitative planar 99mTc-PYP scintigraphy in patients with suspected ATTR-CA, including analysis of extracardiac uptake and temporal stability. In this retrospective study, 174 consecutive patients referred for 99mTc-PYP scintigraphy were analyzed. Inclusion was based on heart failure symptoms and echocardiographic findings suggestive of CA (e.g., wall thickness ≥ 12 mm). Heart-to-contralateral lung (H/CL) and heart-to-mediastinum (H/M) ratios were measured from anterior and left-lateral planar images at 1 and 3 h post-injection. Extracardiac tracer uptake was quantified using soft tissue-to-rib ratios at shoulder, elbow, axilla, and liver sites. Final diagnosis was determined by histopathology and/or validated non-biopsy clinical criteria. H/CL and H/M ratios demonstrated excellent diagnostic performance for identifying ATTR-CA, with AUCs of 0.97 and 0.88, respectively (0.98 and 0.93 in the histologically confirmed subgroup). Both indices were strongly correlated (r > 0.8). H/M values were stable across timepoints (p = 0.22), while H/CL showed a slight but statistically significant decline (1.4 vs. 1.3, p = 0.01). Patients with confirmed ATTR-CA had significantly higher myocardial and selected extracardiac uptake ratios (e.g., elbow/rib, axilla/rib) compared with non-ATTR individuals (p < 0.05). Semi-quantitative 99mTc-PYP planar scintigraphy provides high diagnostic accuracy for ATTR-CA, with the 1-h H/CL ratio showing the highest performance. Lateral H/M projections offer stable measures that improve confidence in cases with sternal overlap. While extracardiac uptake reflects systemic involvement, it currently serves as a hypothesis-generating marker. Incorporating these semi-quantitative metrics into routine workflows supports objective, clinically actionable assessment and may reduce the need for invasive histological confirmation.
No takes yet. Share an insight, caveat, or question.
Imakhanova et al. (2026) conducted a cohort in Suspected transthyretin cardiac amyloidosis (ATTR-CA) (n=174). Semi-quantitative planar 99mTc-PYP scintigraphy vs. Non-ATTR-CA patients was evaluated on Diagnostic accuracy (AUC) of 1-hour heart-to-contralateral lung (H/CL) ratio for identifying ATTR-CA (AUC 0.97, p=<0.001). The 1-hour heart-to-contralateral lung (H/CL) ratio on semi-quantitative 99mTc-PYP planar scintigraphy demonstrated excellent diagnostic accuracy for identifying ATTR-CA with an AUC of 0.97.