Key result
Tc-99m DPD shows more clinical associations than PYP, better reflecting cardiac amyloidosis severity.
Why the study?
Technetium-99 m DPD and Tc-99 m PYP are the two most commonly used radiotracers for cardiac amyloidosis, but no studies have directly compared them.
Does DPD scintigraphy provide different diagnostic and clinical utility compared to PYP scintigraphy in patients with cardiac amyloidosis?
Observational (n=10)
No
Does DPD scintigraphy provide different diagnostic and clinical utility compared to PYP scintigraphy in patients with cardiac amyloidosis?
DPD scintigraphy may better reflect disease severity in cardiac amyloidosis, whereas PYP scintigraphy may be more sensitive for diagnosis.
Answers are grounded in this paper and cite their sources.
Observational associations favor Tc-99m DPD for amyloidosis severity; hypothesis-generating and should not yet change imaging practice.
BACKGROUND: Technetium-99 m 3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) and technetium-99 m sodium pyrophosphate (PYP) are the two most commonly used radiotracers for cardiac amyloidosis (CA), but no studies have directly compared them. Therefore, in this study, we directly compared the diagnostic and clinical utility of DPD and PYP scintigraphy in patients with CA. METHODS: Ten patients with CA were enrolled. Eight clinical variables and 12 scintigraphic parameters were used. Clinical variables were age, sex, estimated glomerular filtration rate (eGFR), N-terminal pro brain natriuretic peptide (NT-proBNP), and the results of electromyography (EMG), a sensory test, electrocardiogram, and echocardiography (EchoCG). Four heart retention ratios (heart/whole-body profile, heart/pelvis, heart/skull, and heart/contralateral lung) were calculated from the DPD and PYP scans and two visual scoring systems (Perugini and Dorbala systems) were used. Comparative analyses were performed between radiotracers and between visual scoring systems using clinical variables and scintigraphic parameters. RESULTS: Twenty DPD parameters and nine PYP parameters had significant associations with age, eGFR, NT-proBNP, EchoCG, and EMG. DPD parameters had more frequent significant associations with clinical variables than PYP parameters. Compared to visual scores in the DPD scan, the proportion of patients with higher visual scores in the PYP scan was relatively greater than those with lower visual scores, and there were more patients with a visual score of 2 or higher in PYP scans than DPD scans. CONCLUSIONS: DPD scintigraphy may reflect the disease severity of CA better than PYP scintigraphy, whereas PYP scintigraphy may be a more sensitive imaging modality for identifying CA involvement.
No takes yet. Share an insight, caveat, or question.
Park et al. (2023) conducted an observational in Cardiac amyloidosis (n=10). Tc-99m DPD scintigraphy vs. Tc-99m PYP scintigraphy was evaluated on Diagnostic and clinical utility based on correlations between scintigraphic parameters and clinical variables. Tc-99m DPD scintigraphy demonstrated more frequent significant associations with clinical variables than Tc-99m PYP scintigraphy, suggesting it better reflects cardiac amyloidosis disease severity.