Observes corneal thickness changes following hypoxia in subjects wearing hydrogel lenses, suggesting insights into recovery times.
Central corneal thickness changes were monitored in nine subjects who wore low water content hydrogel lenses of varying thickness for 3 h in the open and closed eye conditions. At the end of 3 h of lens wear, corneal de‐swelling to prelens thickness for the different levels of hypoxia was determined by pachometry performed every 5 min for the first 30 min, every 10 min for the next 40 min, and every 15 min thereafter. Examination of the individual deswelling profiles indicates (1) a biphasic response in those with corneal edema greater than 14%, and (2) a large portion of the deswelling occurred during the first 30 min, followed by a more gradual rate until baseline was reached. Small amounts of corneal edema (less than 5%) required up to 25 min to return to baseline, whereas 6 to 15% required 30 to 70 min, and 20% required 95 min. The time taken for the cornea to deswell to baseline was linearly related to the amount of corneal swelling (r = 0.88; p < 0.0001).
No takes yet. Share an insight, caveat, or question.
Johnson et al. (1985) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: