Answers are grounded in this paper and cite their sources.
Experiments examine bond-slip behavior in steel-concrete structures, revealing critical insights into anchorage length effects.
To further improve the seismic behavior of high-strength foam concrete filled cold-formed checkered steel composite wall structures, it is crucial to investigate the bond–slip behavior between the cold-formed checkered steel (CFCS) and foam concrete (FC) within the wall. Hence, six CFCSFC specimens were designed and subjected to monotonic and cyclic loading tests to study the influence of anchorage lengths on failure modes, bond strength-slip displacement curves, and characteristic bond strength. Results indicated that with the anchorage length increases, the ultimate bond strength of the specimens continuously decreases, and the specimens exhibit more severe failure under cyclic loading than monotonic loading. Compared to the specimens with a 400 mm anchorage length, the ultimate bond strength decreased by 4.8–9.6% for those with a 500 mm length, and by 10.7–16.0% for those with a 600 mm length. Strain along the inner flange of the steel section generally decreased with increasing anchorage length, with loading end strain significantly exceeding free-end strain. Finite element simulations revealed that specimen failure primarily manifested as steel section yielding when anchorage lengths ranged from 1400 mm to 1800 mm. Furthermore, a calculation formula for characteristic bond strength as a function of anchorage length was proposed.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: