Key result
Transcatheter aortic valve prostheses demonstrated significantly lower flow velocities compared to rapid-deployment valves in a patient-specific 3D-printed aortic phantom.
Why the study?
A lack of uniformity in size labelling and potentially adverse hemodynamic effects emphasize the need for an in-depth comparison of available RDAVR and TAVR prostheses.
Do different rapid-deployment and transcatheter aortic valve prostheses exhibit different hemodynamic profiles in a patient-specific small annulus model?
Do different rapid-deployment and transcatheter aortic valve prostheses exhibit different hemodynamic profiles in a patient-specific small annulus model?
In a patient-specific 3D printed small annulus model, RDAVR and TAVR prostheses exhibited notable differences in hemodynamics, highlighting the need to consider prosthesis-specific fluid dynamics beyond simple annular sizing to reduce prosthesis-patient mismatch.
Answers are grounded in this paper and cite their sources.
May alter valve selection in small-annulus patients to minimize PPM; extends in vitro validation of patient-specific phantoms for preprocedural planning.
Rapid-deployment and transcatheter aortic valve replacement (RDAVR and TAVR) are standard treatment options for aortic valve disease. The lack of uniformity in size labelling and potentially adverse hemodynamic effects emphasize the need for an in-depth comparison of available prostheses. State-of-the-art valves (INTUITY Elite, Perceval, SAPIEN 3 Ultra and Evolut PRO+) were implanted into a patient-specific 3D printed aortic phantom with an annulus size recommended for the evaluated valves. The model was incorporated into a flow loop setup. Analysis of hemodynamic parameters was performed using advanced cardiovascular imaging (4D flow MRI and vector (V) flow ultrasound (US)). US revealed systematic differences in flow rates between RDAVR and TAVR prostheses. 4D flow analysis revealed localized regions of elevated WSS heterogeneously distributed without relevant differences between the prostheses. RDAVR prostheses showed higher kinetic energy loss (EL) along the thoracic aorta in small- compared to large-diameter models. EOA estimations ranged from 2.02 to 2.69 cm² for RDAVR to 1.71 cm² for 23 mm TAVR. Pressure gradients varied strongly between prosthesis types. Blood flow characteristics presented notable differences between the considered prostheses. This interdisciplinary approach provides a foundation for interpreting clinical outcomes after TAVR or RDAVR and potentially reduce the risk of prosthesis-patient mismatch.
No takes yet. Share an insight, caveat, or question.
Grefen et al. (2026) studied Aortic valve disease. Rapid-deployment and transcatheter aortic valve prostheses vs. Comparison between prosthesis types was evaluated on Hemodynamic parameters (flow velocity, wall shear stress, pressure gradient, kinetic energy loss, effective orifice area). Transcatheter aortic valve prostheses demonstrated significantly lower flow velocities compared to rapid-deployment valves in a patient-specific 3D-printed aortic phantom.