Key result
Higher catheter contact force compliance during PVI predicts ~5% lower late AF recurrence risk.
Why the study?
The study was conducted to investigate the predictive value of catheter ablation parameters during PVI on long-term recurrence in patients with paroxysmal AF.
Does contact force compliance rate predict late AF recurrence in patients with paroxysmal atrial fibrillation undergoing catheter ablation?
Does contact force compliance rate predict late AF recurrence in patients with paroxysmal atrial fibrillation undergoing catheter ablation?
Maintaining a stable contact force compliance rate during radiofrequency ablation for paroxysmal atrial fibrillation is independently associated with a reduced risk of late AF recurrence.
High CF compliance during PVI may reduce AF recurrence; extends prior data but leaves open benefit of targeting it.
Background: To investigate the predictive value of catheter ablation parameters during pulmonary vein isolation (PVI) on long-term recurrence in patients with paroxysmal atrial fibrillation (pAF). Methods: A retrospective analysis was conducted on 386 pAF patients who underwent initial catheter-based radiofrequency ablation (RFA) for PVI. After excluding ineligible cases and those lost to follow-up, 150 patients were included (mean follow-up: 28.86 ± 3.03 months). Patients were divided into recurrence and AF-free groups. Ablation parameters including catheter contact force (CF), ablation index (AI), and GAPs were collected via the CARTO VISITAG Module, and Cox regression was used to identify recurrence predictors. Results: The 2-year AF recurrence rate was 13.33% (20/150). No significant differences in baseline clinical characteristics, AI compliance rate, VISITAG GAP incidence, ablation points and time, or complication rates were observed between groups (p > 0.05). However, CF compliance rate was significantly lower in the AF recurrence group compared to AF-free group (79.17% vs. 90.10%, p < 0.001), and it was an independent predictor of late AF recurrence (HR = 0.950, 95%CI: 0.919–0.981; p = 0.002). Conclusion: CF compliance rate is independently associated with late AF recurrence after PVI. Maintaining stable CF during ablation may promote durable lesions and potentially reduce recurrence risk.
No takes yet. Share an insight, caveat, or question.
Xie et al. (2026) studied this question. Catheter contact force compliance rate during pulmonary vein isolation independently predicted late atrial fibrillation recurrence (HR 0.950, 95% CI 0.919-0.981).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: