Do low contact force and dragging ablation technique increase the risk of arrhythmia recurrence in patients undergoing de-novo pulmonary vein isolation for atrial fibrillation?
Do low contact force and dragging ablation technique increase the risk of arrhythmia recurrence in patients undergoing de-novo pulmonary vein isolation for atrial fibrillation?
Low contact force and dragging ablation technique are associated with higher rates of arrhythmia recurrence after de-novo pulmonary vein isolation for atrial fibrillation.
Answers are grounded in this paper and cite their sources.
Low contact force and dragging may raise post-PVI recurrence risk; hypothesis-generating and should not yet change practice.
OBJECTIVES: Recurrent arrhythmia after pulmonary vein isolation (PVI) by radiofrequency (RF) ablation in patients with atrial fibrillation (AFIB) remains a significant challenge. Using contact force (CF) sensing ablation catheters, we aimed to identify procedure related parameters associated with recurrence after de-novo PVI in patients with AFIB. METHODS: Consecutive patients undergoing a de-novo PVI procedure (n = 120, 63% paroxysmal and 37% persistent AFIB) employing a force-sensing ablation catheter were included. A clinical control including electrocardiogram and 120 hour of Holter-recording at 12-months was performed in all patients. Recurrence was defined as any documented AFIB or atrial flutter more than 30 seconds on Holter-recording after an initial blanking period of three months. RESULTS: Recurrence occurred in 44 patients (37%). Mean CF was lower in patients with recurrent arrhythmia (22.2 ± 9.5 vs. 28.8 ± 9.3 g, p < .001). In multi-variable analyses lower mean CF (OR 0.9 (95% CI 0.8-1.0), p = .03), and higher percentage of ablation time with a CF <10 grams (OR 1.1 (95% CI 1.0-1.1), p = .004) were both associated with recurrence in two distinct models. Dragging during ablation compared with point-by-point ablation technique was associated with recurrence in both models (OR 19.2 (95% CI 2.9-130.0), p = .002, and OR 21.7 (95% CI 2.7-176.2), p = .004). CONCLUSIONS: Low CF and dragging during ablation as compared with point-by-point ablation technique were associated with recurrent arrhythmia in patients with AFIB undergoing de-novo PVI by RF ablation.
No takes yet. Share an insight, caveat, or question.
Tofig et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: