Why the study?
Does feature tracking CMR accurately quantify left ventricular strains and torsion compared to DENSE CMR?
Does feature tracking CMR accurately quantify left ventricular strains and torsion compared to DENSE CMR?
Current feature tracking technology has limited utility for quantifying cardiac mechanics compared to DENSE CMR.
Answers are grounded in this paper and cite their sources.
Feature tracking warrants caution for LV strain/torsion assessment in practice; leaves open needs for prospective validation against DENSE.
Compared to DENSE as a reference standard, feature tracking was inaccurate for quantification of apical and basal LV circumferential strains, longitudinal strain, torsion, and dyssynchrony. Feature tracking was only accurate for quantification of mid LV circumferential strain. Moreover, feature tracking is unnecessary for quantification of whole-slice strains (e.g. base, apex), since simplified processing of only ED and ES contours yields very similar results to those derived from feature tracking. Current feature tracking technology therefore has limited utility for quantification of cardiac mechanics.
No takes yet. Share an insight, caveat, or question.
Wehner et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: