Numerical simulations optimize dark current performance in mid-wave infrared photodetectors, indicating effective barrier design.
In this work, a high-performance mid-wave infrared (MWIR) photodetector (PD) utilizing an InAs/GaSb Type-II superlattice absorber and a quaternary AlGaAsSb barrier is designed and analyzed based on numerical simulations aimed at determining an optimized detector structure. Through these simulations, the composition of the AlGaAsSb barrier is carefully designed to achieve lattice matching, high conduction band offset and zero valence band offset. By optimizing the barrier thickness and doping concentration, the depletion region is effectively shifted from the narrow-bandgap absorber to the wide-bandgap barrier; additionally, at 150 K and a reversed bias of 0.05 V, the dark current density in the PD with the barrier (pBn) is reduced to 1.83 × 10−5 A/cm2, about two orders of magnitude lower than that of the PD without the barrier. Furthermore, the effect of the barrier on the generation–recombination (G-R) and the trap-assisted tunneling (TAT) currents are analyzed and compared in detail, and it is found that the barrier structure is much more effective in suppressing the TAT current at low reversed bias when the electric field is low in the absorber layer. These results demonstrate the efficacy of the proposed AlGaAsSb barrier design for realizing high-operating-temperature MWIR PDs. It also provides an insight into the physical mechanism that leads to the performance enhancement of InAs/GaSb PDs.
No takes yet. Share an insight, caveat, or question.
Jiao et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: