Retrospective planning study compares LINAC-based SRS techniques and Gamma Knife, highlighting dosimetric performance.
Background/Objectives: LINAC-based single-isocenter (SIT) stereotactic radiosurgery (SRS) enables efficient treatment of multiple brain metastases but may compromise target conformity and increase low-dose brain exposure, particularly for spatially distributed lesions. Dual-isocenter techniques (DITs) may mitigate these limitations, while Gamma Knife (GK) remains the reference standard for high-selectivity radiosurgery. This study compares SIT- and DIT LINAC-based SRS with GK, focusing on target conformity and low-dose brain exposure under equivalent, zero-margin targeting assumptions. Methods: Twenty-eight patients with multiple brain metastases (197 lesions) were included in this retrospective planning study. For each patient, three plans were generated: a GK plan and LINAC-based SIT and DIT plans using automated dynamic conformal arc optimization (Elements Multiple Brain Metastases). All plans were generated using a zero-millimeter GTV-to-PTV margin strategy. For DIT, lesions were automatically clustered and assigned to two isocenters. Target coverage required ≥99% of each GTV to receive the prescription dose. Plan quality was evaluated using the Paddick Conformity Index (PCI) on a per-lesion basis and low-dose brain volumes (V12, V10, V5, V4, and V3 Gy) on a per-patient basis. Paired non-parametric tests and multivariable models were used to assess technique-related differences and associations with total target volume and lesion count. Results: GK achieved the highest median PCI (0.83), followed closely by DIT (0.77), while SIT plans demonstrated significantly lower conformity (0.73). Compared with GK, the median PCI difference was −0.05 for DIT and −0.08 for SIT. Conformity for DIT remained stable across lesion volumes and lesion counts, whereas GK conformity increased modestly with lesion size. Low-dose brain exposure differed significantly between techniques at all dose levels (p < 0.001). GK consistently yielded the lowest Vx volumes, SIT the highest, and DIT intermediate values. Relative to GK, SIT plans showed progressively larger increases in low-dose exposure at lower dose levels (mean ΔV3 ≈ +149 cc), while DIT reduced this low-dose spread (mean ΔV3 ≈ +117 cc). Total target volume was the dominant predictor of low-dose brain exposure across all techniques, with a smaller additional contribution from lesion count. Conclusions: DIT LINAC-based SRS significantly improves target conformity and reduces low-dose brain exposure compared with SIT delivery, achieving dosimetric performance that closely approximates Gamma Knife under equivalent zero-margin targeting assumptions. While Gamma Knife remains the reference standard for low-dose sparing, dual-isocenter planning represents a clinically robust and scalable alternative that effectively balances plan quality and treatment efficiency in patients with multiple brain metastases.
No takes yet. Share an insight, caveat, or question.
Teixeira et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: