Why the study?
Is robot-assisted aortic valve surgery safe and feasible for patients requiring aortic valve intervention?
Is robot-assisted aortic valve surgery safe and feasible for patients requiring aortic valve intervention?
Robot-assisted aortic valve surgery, including totally endoscopic approaches and tumor resections, appears safe and feasible with excellent early clinical results.
Supports preliminary safety of robotic aortic valve surgery; hypothesis-generating and should not yet change practice.
Robotic cardiac surgery was FDA-approved in 2002 and since then several different procedures have been performed to facilitate a truly minimally invasive approach. The use of robotics in aortic valve surgery, however, is still in its infancy. In this article, we report our clinical experience and chronological development with robot-assisted aortic valve surgery. This includes a description of how robotic assistance was gradually integrated during right mini-thoracotomy aortic valve replacement, a series of cases in which the robot was docked for parts of the procedure, a single case of a totally endoscopic robot-assisted aortic valve replacement with a stentless valve, and three cases of aortic valve papillary fibroelastoma resections. All of these were performed safely with early postoperative recovery and excellent clinical results. Additionally, we review the latest literature describing robot-assisted aortic valve surgery. Finally, we describe current issues, and challenges for robot-assisted aortic valve surgery.
No takes yet. Share an insight, caveat, or question.
Balkhy et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: