Key result
Ensemble deep learning model classifies ~92% of atrial high-rate episodes with near-zero errors.
Why the study?
Remote monitoring of pacemakers and defibrillators increases clinical workload, especially demanding review of atrial high-rate episodes which can contain AT/AF, noise, or far-field oversensing.
Does a multi-center trained ensemble 1D-ResNet10 deep learning model accurately classify atrial high-rate episodes (AT/AF, noise, and far-field oversensing) and reduce clinical review workload in remotely monitored patients with Biotronik pacemakers and ICDs?
Observational (n=1,264)
Blinded expert adjudication of AHRE episodes
Yes
Does a multi-center trained ensemble 1D-ResNet10 deep learning model accurately classify atrial high-rate episodes (AT/AF, noise, and far-field oversensing) and reduce clinical review workload in remotely monitored patients with Biotronik pacemakers and ICDs?
Answers are grounded in this paper and cite their sources.
An ensemble 1D-ResNet10 model can automatically adjudicate 92% of pacemaker and ICD atrial high-rate episodes with <0.1% error and 100% AT/AF sensitivity at a >95% probability threshold, potentially reducing remote monitoring workload by 92%.
Remote monitoring of pacemakers and defibrillators increases patient safety but also increases clinical workload. Review of atrial high-rate episodes is particularly demanding as episodes can contain atrial tachycardia or atrial fibrillation (AT/AF), noise, or far-field oversensing (FFO). Automatic review of atrial high-rate episodes by an Artificial Intelligence (AI) model can decrease the workload of remote monitoring, provided it maintains high sensitivity for true atrial tachycardia. A residual network is trained using a center-level fourfold cross validation. The four resulting models achieved a precision of 97.2–99.4% for AT/AF, 93.1–97.7% for noise, and 75.4–94.4% for FFO, while maintaining high sensitivity 98.9–99.3% for AT/AF. The four models were combined through averaging prediction probabilities to create an ensemble model. Thresholding ensemble predictions with probability > 95% resulted in a robust ensemble model that made only two errors (<0.1%) after reviewing 3925 episodes (91.9%) of the total 4271 episodes. This shows how AI models can reliably assist in remote monitoring. Future research should be aimed at classification models for other episode types and clinical validation of AI models to assist remote monitoring of pacemakers and defibrillators.
No takes yet. Share an insight, caveat, or question.
Krimpen et al. (2026) conducted an observational in Atrial high-rate episodes in remotely monitored pacemakers and implantable cardiac defibrillators (n=1,264). Ensemble 1D-ResNet10 deep learning model for automatic classification of atrial high-rate episodes vs. Blind adjudication by two remote monitoring experts (with a third expert adjudicating disagreements) was evaluated on Classification performance (sensitivity, precision, and error rate) for atrial tachycardia/atrial fibrillation (AT/AF), noise, and far-field oversensing (FFO) on the external test set at >95% prediction probability threshold. The ensemble 1D-ResNet10 model classified 91.9% (3,925/4,271) of external atrial high-rate episodes at >95% probability with <0.1% errors (2/3,925) and 100% sensitivity for AT/AF.
Synapse has enriched 10 related papers. Consider them for comparative context: