February 12, 2015AnaesthesiaOpen Access

The predictive ability of non‐invasive haemodynamic parameters for hypotension during caesarean section: a prospective observational study

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Do pre-anaesthetic non-invasive haemodynamic parameters predict hypotension in parturients undergoing caesarean section with spinal anaesthesia?

Population

81 parturients undergoing caesarean section with spinal anaesthesia

Design

Cohort

Authors

MYMasashi YokoseYokohama City University HospitalTMTakahiro MiharaKishokai Medical CorporationYSYoh SugawaraYokohama City University Medical Center

Discussion

Loading...

Member takes

Implication

Pre-anaesthetic heart rate may stratify hypotension risk; hypothesis-generating and should not yet alter practice.

Structured PICO

Do pre-anaesthetic non-invasive haemodynamic parameters predict hypotension in parturients undergoing caesarean section with spinal anaesthesia?

P
Population
81 parturients undergoing caesarean section with spinal anaesthesia
I
Intervention
Measurement of pre-anaesthetic non-invasive haemodynamic parameters (pulse oximetry perfusion index, pleth variability index, heart rate, ratio of low-frequency to high-frequency components of heart rate variability, and entropy of heart rate variability)
O
Outcome
Hypotension during caesarean sectionsafety

Pre-anaesthetic heart rate is an independent predictor of hypotension during caesarean section under spinal anaesthesia, whereas pulse oximetry and heart rate variability parameters are not.

Cite This Study

Yokose et al. (2015) studied this question.

synapsesocial.com/papers/69d56d2975589c71d767cfb0https://doi.org/10.1111/anae.12992
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteers2008 · 117 citations
  2. 2Differential Effects of Propofol and Sevoflurane on Heart Rate Variability2003 · 296 citations
  3. 3Correlation between heart rate variability and haemodynamic fluctuation during induction of general anaesthesia: comparison between linear and non‐linear analysis*2007 · 20 citations
  4. 4Preoperative Ultra Short-Term Entropy Predicts Arterial Blood Pressure Fluctuation During the Induction of Anesthesia2007 · 21 citations
  5. 5A new look at the statistical model identification1974 · 51,750 citations