Percutaneous transcatheter closure using an Amplatzer Duct Occluder 2 device is a feasible approach for treating aortic prosthetic paravalvular leaks in patients presenting with heart failure.
Answers are grounded in this paper and cite their sources.
May offer percutaneous option for heart failure from aortic paravalvular leaks; leaves open validation in larger cohorts.
Paravalvular leaks (PVLs) are a well-recognized complication of prosthetic valve replacement. Perivalvular prosthetic regurgitation causes significant morbidity and is associated with high perioperative mortality if open surgical repair is required. PVLs manifest with symptoms of congestive heart failure, hemolysis, or in most cases, the combination of both. In recent years, the development of imaging and device techniques significantly shortened the duration of fluoroscopy and procedure success was achieved. Percutaneous transcatheter closure of PVLs with a specific device causes symptomatic improvement. We present a case of transcatheter closure of aortic paravalvular insufficiency with amplatzer duct occluder 2 device.
No takes yet. Share an insight, caveat, or question.
Ösken et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: