Key result
Adding low-voltage-area ablation to PVI fails to improve 1-year AF recurrence-free survival.
Why the study?
The efficacy of low-voltage-area ablation in addition to pulmonary vein isolation on rhythm outcomes in patients with paroxysmal AF had not been well determined.
Does low-voltage-area ablation in addition to pulmonary vein isolation improve 1-year AF-recurrence-free survival in patients with paroxysmal atrial fibrillation?
RCT (n=398)
1:1 fashion
Does low-voltage-area ablation in addition to pulmonary vein isolation improve 1-year AF-recurrence-free survival in patients with paroxysmal atrial fibrillation?
In patients with paroxysmal atrial fibrillation and low-voltage areas, performing additional LVA ablation after pulmonary vein isolation does not improve 1-year freedom from AF recurrence.
Answers are grounded in this paper and cite their sources.
Additional LVA ablation adds no benefit to PVI for paroxysmal AF; challenges routine use and reinforces PVI-alone arms in future trials.
Background The efficacy of low-voltage-area (LVA) ablation has not been well determined. This study aimed to investigate the efficacy of LVA ablation in addition to pulmonary vein isolation on rhythm outcomes in patients with paroxysmal atrial fibrillation (AF). Methods and Results VOLCANO (Catheter Ablation Targeting Low-Voltage Areas After Pulmonary Vein Isolation in Paroxysmal Atrial Fibrillation Patients) trial included paroxysmal AF patients undergoing initial AF ablation. Of 398 patients in whom a left atrial voltage map was obtained after pulmonary vein isolation, 336 (85%) had no LVA (group A). The remaining 62 (15%) patients with LVAs were randomly allocated to undergo LVA ablation (group B, n=30) or not (group C, n=32) in a 1:1 fashion. Primary end point was 1-year AF-recurrence-free survival rate. No adverse events related to LVA ablation occurred. Procedural (124±40 versus 95±33 minutes, P=0.003) and fluoroscopic times (29±11 versus 24±8 minutes, P=0.034) were longer in group B than group C. Patients with LVAs demonstrated lower AF-recurrence-free survival rates (88%) than those without LVA (B, 57%, P<0.0001; C, 53%, P<0.0001). However, LVA ablation in addition to pulmonary vein isolation did not impact AF-recurrence-free survival rate (group B versus C, P=0.67). Conclusions The presence of LVA was a strong predictor of AF recurrence after pulmonary vein isolation in patients with paroxysmal AF. However, LVA ablation had no beneficial impact on 1-year rhythm outcomes. Registration URL: https://www.umin.ac.jp/ctr; Unique identifier: UMIN000023403.
No takes yet. Share an insight, caveat, or question.
Masuda et al. (2020) conducted an RCT in Paroxysmal atrial fibrillation (n=398). Low-voltage-area ablation in addition to pulmonary vein isolation vs. Pulmonary vein isolation alone was evaluated on 1-year AF-recurrence-free survival rate (p=0.67). Low-voltage-area ablation added to pulmonary vein isolation did not improve 1-year AF-recurrence-free survival in paroxysmal AF patients with LVAs.
Synapse has enriched 10 related papers. Consider them for comparative context: