The dynamo-type high-temperature superconducting (HTS) flux pump enables the injection of direct current (dc) into a closed-loop HTS coil. In this study, based on a two-dimensional segregated H-formulation finite-element method model, we numerically investigate the impact of the number of permanent magnets (PMs) mounted on the rotor on its performance. We find that the dc output voltage ( <tex-math notation="LaTeX">VDC</tex-math> ) does not always increase with increasing PM number as reported previously. More specifically, above a certain value, which is determined by the size of the PMs and the rotor, the dc output voltage no longer increases with the PMs number and tends to decrease continuously. With the further increase of the PM number, the dc output voltage will even disappear and then increase with the opposite polarity. We attribute the underlying mechanism of this phenomenon to the change in the profile of the magnetic field applied to the HTS stator when increasing the number of PMs. Specifically, there is an optimal value of the number of PMs to achieve the best performance, which will enable better design of such HTS dynamos in the future.