Why the study?
Using peripheral Doppler surrogates to infer LVOT VTI and guide fluid management raises important aspects of Doppler flow, insonation error, and the relationship between central and peripheral flow.
Key points are not available for this paper at this time.
Design
Review
Answers are grounded in this paper and cite their sources.
May support peripheral Doppler as LVOT VTI surrogate for fluid management; leaves open prospective validation before clinical adoption.
The left ventricular outflow tract velocity time integral (LVOT VTI) is commonly used in the intensive care unit as a measure of stroke volume (SV) and how the SV changes in response to an intervention; therefore, the LVOT VTI is used to guide intravenous fluid management. Various peripheral Doppler surrogates are proposed to infer the LVOT VTI (e.g., measures from the common carotid artery). A recently-described, novel method of insonation has an excellent ability to detect change in the LVOT VTI. This approach raises important facets of Doppler flow and insonation error, as well as the general principles at play when using a peripheral artery to infer changes from the left ventricle. Relating the VTI of a peripheral artery to the LVOT VTI was recently described mathematically and may help clinicians think about the Doppler relationship between central and peripheral flow.
No takes yet. Share an insight, caveat, or question.
Jon‐Émile S. Kenny (2024) studied this question.