Key result
LBBAP after TTVR demonstrates feasibility and excellent short-term safety while maintaining valve integrity.
Why the study?
Conduction disturbances requiring pacemaker implantation occur in up to 24.7% of patients after transcatheter tricuspid valve replacement, but left bundle branch area pacing has not been systematically evaluated post-TTVR.
Is left bundle branch area pacing safe and feasible in patients requiring pacing after transcatheter tricuspid valve replacement?
Case Report (n=2)
Is left bundle branch area pacing safe and feasible in patients requiring pacing after transcatheter tricuspid valve replacement?
Left bundle branch area pacing is a feasible and safe short-term pacing strategy for patients developing high-grade AV block after transcatheter tricuspid valve replacement, without compromising valve integrity.
Offers a preliminary pacing option for patients requiring conduction support post-TTVR;.
BACKGROUND: Transcatheter tricuspid valve replacement (TTVR) is a novel therapy for severe tricuspid regurgitation. However, conduction disturbances requiring pacemaker implantation occur in up to 24.7% of patients. Left bundle branch area pacing (LBBAP) has not been systematically evaluated post-TTVR, where lead passage across the prosthesis may compromise valve integrity. The objective of this paper was to report the feasibility, safety, and performance of LBBAP after TTVR. CASE SUMMARY: Two pacemaker-naïve patients requiring pacing post-TTVR were retrospectively analyzed. DISCUSSION: Both patients underwent TTVR and developed high-grade atrioventricular block within 72 hours. LBBAP was successful in both cases with no procedural-related complications. At 30 days, pacing parameters remained unchanged with no device-related adverse events. Echocardiography at 1 and 30 days demonstrated ≤ mild tricuspid regurgitation, no lead-valve interaction, and stable right ventricular function. TAKE-HOME MESSAGES: LBBAP post-TTVR is feasible with excellent short-term safety and performance while maintaining valve integrity. Our series reinforces its safety and adds systematic echocardiographic follow-up.
No takes yet. Share an insight, caveat, or question.
Kamareddine et al. (2026) conducted a case report in High-grade atrioventricular block post-transcatheter tricuspid valve replacement (n=2). Left bundle branch area pacing (LBBAP) was evaluated on Feasibility, safety, and performance.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: