Why the study?
Left ventricular volumes and LVEF are key in HFrEF evaluation, but whether in-training echocardiographers provide feasible and more reproducible results with 3-DE versus 2-DE was unknown.
Does 3-dimensional echocardiography improve the reproducibility of left ventricular volume and ejection fraction measurements compared to 2-dimensional echocardiography for in-training echocardiographers in patients with HFrEF?
Does 3-dimensional echocardiography improve the reproducibility of left ventricular volume and ejection fraction measurements compared to 2-dimensional echocardiography for in-training echocardiographers in patients with HFrEF?
Answers are grounded in this paper and cite their sources.
3-D echocardiography is a feasible, rapidly learned, and more reproducible method than 2-D echocardiography for assessing left ventricular volumes and ejection fraction in HFrEF patients, even for in-training echocardiographers.
Left ventricular volumes (LVVs) and ejection fraction (LVEF) are key elements in the evaluation and follow-up of patients with heart failure with reduced ejection fraction (HFrEF). Therefore, a feasible and reproducible imaging method to be used by both experienced and in-training echocardiographers is mandatory. Our aim was to establish if, in a large echo lab, echocardiographers in-training provide feasible and more reproducible results for the evaluation of patients with HFrEF when using 3-dimensional echocardiography (3-DE) versus 2-dimensional echocardiography (2-DE). Sixty patients with HFrEF (46 males, age: 58 ± 17 y) underwent standard transthoracic 2-D acquisitions and 3-D multibeat full volumes of the left ventricle. One expert user in echocardiography (expert) and three echocardiographers with different levels of training in 2-DE (beginner, medium and advanced) measured the 2-D LVVs and LVEFs on the same consecutive images of patients with HFrEF. Afterward, the expert performed a 1-mo training in 3-DE analysis of the users, and both the expert and trainees measured the 3-D LVVs and LVEF of the same patients. Measurements provided by the expert and all trainees in echo were compared. Six patients were excluded from the study because of poor image quality. The mean end-diastolic LVV of the remaining 54 patients was 214 ± 75 mL with 2-DE and 233 ± 77 mL with 3-DE. Mean LVEF was 35 ± 10% with 2-DE and 33 ± 10% with 3-DE. Our analysis revealed that, compared with the expert user, the trainees had acceptable reproducibility for the 2-DE measurements, according to their level of expertise in 2-DE (intra-class coefficients [ICCs] ranging from 0.75 to 0.94). However, after the short training in 3-DE, they provided feasible and more reproducible measurements of the 3-D LVVs and LVEF (ICCs ranging from 0.89-0.97) than they had with 2-DE. 3-DE is a feasible, rapidly learned and more reproducible method for the assessment of LVVs and LVEF than 2-DE, regardless of the basic level of expertise in 2-DE of the trainees in echocardiography. In echo labs with a wide range of staff experience, 3-DE might be a more accurate method for the follow-up of patients with HFrEF.
No takes yet. Share an insight, caveat, or question.
Mihaila et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: