Why the study?
Older high containment facilities housing FMDV, SVDV, or CSFV may not be suited for fumigation during decommissioning, making heat treatment a potential alternative.
Does heat treatment at 70 °C inactivate FMDV, SVDV, and CSFV on glass and plastic surfaces compared to room temperature?
Does heat treatment at 70 °C inactivate FMDV, SVDV, and CSFV on glass and plastic surfaces compared to room temperature?
Answers are grounded in this paper and cite their sources.
Heat treatment at 70 °C for 24-48 hours effectively inactivates FMDV, SVDV, and CSFV on glass and plastic surfaces, providing an alternative decontamination method for facilities.
Foot-and-mouth disease virus (FMDV), swine vesicular disease virus (SVDV) and classical swine fever virus (CSFV) all cause important animal diseases. FMDV affects many different cloven-hoofed animals, whereas SVDV and CSFV are restricted to domestic and feral pigs together with wild boar. Europe is normally free of these diseases, but occasionally outbreaks happen, which can cause huge economic losses. Handling of these viruses, in particular FMDV and CSFV, is only allowed within high containment laboratories and stables. Periodically such facilities need to be decommissioned for repair or closing down, which is done by cleaning and chemical disinfection, followed by fumigation due to residual risk from virus on surfaces in inaccessible places. However, building materials in older laboratories or stables that have housed infected animals may not be well-suited for fumigation. Heat treatment is another way of inactivating viruses. In this study, we have determined the survival of infectivity in air-dried virus samples on glass and plastic surfaces incubated at room temperature or heated to 70 °C for 1, 2, 3, 5 and 7 days. Each of the tested viruses was inactivated to below the limit of detection after 24 h or 48 h of incubation at 70 °C; in contrast, some of these viruses were still infectious after 7 days of incubation at room temperature. This study provides important information that can be used in relation to decontamination of buildings and in risk-assessments.
No takes yet. Share an insight, caveat, or question.
Kristensen et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: