Why the study?
Patients with surgically corrected d-TGA have an increased risk of pacing requirement, but there is limited published experience of leadless Micra pacemaker implantation in this population.
Leadless pacemaker implantation can be successfully performed in patients with d-TGA and prior Senning procedure using 3D modeling to navigate complex anatomy.
Answers are grounded in this paper and cite their sources.
May support 3D-guided Micra implantation in complex d-TGA anatomy; hypothesis-generating and requires validation in larger cohorts.
Leadless pacemakers have been developed with key advantages over traditional transvenous pacemakers by substantially mitigating the risks of device infection and lead related complications, and providing an alternative pacing strategy in patients with barriers to superior venous access. The Medtronic Micra leadless pacing system is designed for implantation through a femoral venous approach across the tricuspid valve, via Nitinol tine fixation into the trabeculated subpulmonic right ventricle. Patients with surgically corrected dextro-transposition of the great arteries (d-TGA) have an increased risk of pacing requirement. There is limited published experience of implantation of leadless Micra pacemakers in this population, with key challenges relating to trans-baffle access, and deployment of the device into the less trabeculated subpulmonic left ventricle. Here we describe a case report of leadless Micra implantation in a 49 year old male with d-TGA and Senning procedure in childhood, who required pacing for symptomatic sinus node disease, with anatomic barriers to transvenous pacing. Micra implantation was successfully performed following careful consideration of patient anatomy, including the utilisation of 3D modelling to guide the implantation procedure.
No takes yet. Share an insight, caveat, or question.
Lancini et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: