Answers are grounded in this paper and cite their sources.
Fifteen configurations of a Savonius rotor wind turbine were tested in the Vought Corporation Systems Division 4.9- x 6.1-m Low Speed Wind Tunnel to determine aerodynamic performance. The range of values of the varied parameters was as follows: number of buckets, 2 and 3; nominal freestream velocity, 7 and 14 m/s; Reynolds number per meter, 4.32 x 10/sup 5/ and 8.67 x 10/sup 5/; rotor height, 1 and 1.5 m; rotor diameter (nominal), 1 m; bucket overlap, 0.0 to 0.1 m. The measured test variables were torque, rotational speed, and tunnel conditions. It is concluded that increasing Reynolds number and/or aspect ratio improves performance. The recommended configuration consists of two sets of two-bucket rotors, rotated 90 deg apart, with each rotor having a dimensionless gap width of 0.1 to 0.15.
No takes yet. Share an insight, caveat, or question.
Sheldahl et al. (1978) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: