Answers are grounded in this paper and cite their sources.
Teledyne’s H4RG, H2RG, and H1RG near-infrared array detectors provide reference pixels embedded in their data streams. Although they do not respond to light, the reference pixels electronically mimic normal pixels and track correlated read noise. We describe how the reference pixels can be used with linear algebra and training data to optimally reduce correlated read noise. Simple improved reference subtraction (SIRS) works with common detector clocking patterns and, when applicable, relies only on postprocessing existing data so long as the reference pixels are available. The resulting reference correction is optimal, in a least squares sense, when the embedded reference pixels are the only references and the reference columns on the left and right are treated as two reference streams. We demonstrate SIRS using H4RG ground test data from the Nancy Grace Roman Space Telescope Project. The Julia language SIRS software is freely available for download from the NASA GitHub. The package includes a python-3 “backend” that can be used to apply SIRS corrections if a SIRS calibration file has been provided by the instrument builders.
No takes yet. Share an insight, caveat, or question.
Rauscher et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: