Key result
Anabolic-androgenic steroid use in resistance trained individuals was associated with significantly higher calibrated integrated backscatter compared to non-users.
Why the study?
Does Anabolic-Androgenic Steroid use affect calibrated integrated backscatter and correlate with altered left ventricular and left atrial structure and function in resistance trained individuals?
Cross-Sectional (n=141)
Does Anabolic-Androgenic Steroid use affect calibrated integrated backscatter and correlate with altered left ventricular and left atrial structure and function in resistance trained individuals?
Answers are grounded in this paper and cite their sources.
In resistance trained individuals, AAS use is associated with higher calibrated integrated backscatter, which correlates with altered LV geometry and diastolic function, suggesting its potential utility as a marker for early cardiac risk.
PURPOSE: The use of Anabolic-Androgenic Steroids (AAS) is well documented in resistance trained individuals, despite reports of myocardial inflammation and fibrosis. Calibrated integrated backscatter (ciB) is an echocardiographic technique to measure ultrasonic reflectivity of the left ventricular (LV) myocardium and is a marker for tissue characterization. This study assessed ciB in both AAS using and non-using resistance trained individuals and documented any relationship to LV and left atrial (LA) structure and function. METHODS: Male (n = 120) and female (n = 21) resistance trained individuals (age 30 ± 7 years); current (CU; n = 95) and non-users (NU; n = 46) of AAS were recruited. Comprehensive echocardiography with strain imaging was performed. ciB was measured from a parasternal long axis and LA stiffness index (E/E'/LA reservoir strain) and left atrioventricular coupling index (LA end-diastolic volume/LV end-diastolic volume) were calculated. RESULTS: (134) = 0.246, p = 0.004), and left atrioventricular coupling index (r(134) = 0.241, p = 0.005). ciB was not associated with any LV systolic functional parameter (global longitudinal strain or ejection fraction). CONCLUSIONS: Resistance trained individuals using AAS have significantly higher ciB than non-users, suggesting differential myocardial tissue characteristics within this population. The presence of higher levels of ciB was significantly associated with LV geometry and LV diastolic function which may indicate a role of ciB in identifying early cardiac risk in this population.
No takes yet. Share an insight, caveat, or question.
Place et al. (2026) conducted a cross-sectional in Resistance trained individuals (n=141). Anabolic-Androgenic Steroids (AAS) vs. Non-users of AAS was evaluated on Calibrated integrated backscatter (ciB) and its association with left ventricular and left atrial structure and function. Anabolic-androgenic steroid use in resistance trained individuals was associated with significantly higher calibrated integrated backscatter compared to non-users.
Synapse has enriched 10 related papers. Consider them for comparative context: