Key result
Single Perclose cuts major vascular complications ~47% versus dual Perclose and other closure devices in TF-TAVR.
Why the study?
Does a single Perclose strategy reduce major vascular complications compared to dual Perclose, MANTA, or Prostar XL in patients undergoing TF-TAVR?
Meta-Analysis (n=16,503)
Does a single Perclose strategy reduce major vascular complications compared to dual Perclose, MANTA, or Prostar XL in patients undergoing TF-TAVR?
A single Perclose strategy, with or without adjunct devices, demonstrates superior safety in reducing major vascular complications for large-bore femoral access closure after TF-TAVR compared to dual Perclose, MANTA, or Prostar XL.
Answers are grounded in this paper and cite their sources.
Supports single Perclose ± Angio-Seal for large-bore TF-TAVR closure; extends meta-analytic evidence for optimized vascular access.
BACKGROUND AND AIMS: Large-bore femoral access is commonly required in transfemoral transcatheter aortic valve replacement (TF-TAVR), but vascular access complications remain prevalent, impacting patient outcomes. Various vascular closure devices (VCDs) are used for hemostasis, including the suture-based Prostar XL, Perclose ProGlide, and ProStyle, and the plug-based MANTA device. However, comprehensive comparative evidence on these VCDs, particularly single Perclose strategies, is lacking. METHODS: A systematic review and network meta-analysis were conducted according to PRISMA guidelines. We included randomized and observational studies comparing the safety and efficacy of VCDs for large-bore femoral access closure in TF-TAVR patients. Primary outcomes included major vascular complications; secondary outcomes included major and minor bleeding, minor vascular complications, VCD failure, and all-cause mortality. Frequentist and Bayesian analyses were performed using a random-effects model, with additional subgroup analyses of single Perclose strategies. RESULTS: Thirty-five studies comprising 16,503 patients met inclusion criteria. The single Perclose strategy, with or without adjunct Angio-Seal or FemoSeal, significantly reduced major vascular complications compared to dual Perclose (RR: 1.9, 95% CI [1.2-3.01]), MANTA (RR: 1.89, 95% CI [1.03-3.48]), and Prostar XL (RR: 3.46, 95% CI [1.94-6.18]). Among secondary outcomes, single Perclose also ranked highest in reducing minor complications and bleeding. CONCLUSION: Single Perclose strategies, especially when combined with Angio-Seal, demonstrated superior safety and efficacy for large-bore femoral access closure following TF-TAVR. These findings support the need for further randomized trials to validate single Perclose as a primary approach in TF-TAVR vascular closure.
No takes yet. Share an insight, caveat, or question.
Upadhaya et al. (2025) conducted a meta-analysis in Transfemoral transcatheter aortic valve replacement (TF-TAVR) (n=16,503). Single Perclose strategy vs. Dual Perclose, MANTA, and Prostar XL was evaluated on Major vascular complications (RR 1.9, 95% CI 1.2-3.01). A single Perclose strategy reduced major vascular complications compared to dual Perclose, MANTA, and Prostar XL following TF-TAVR.
Synapse has enriched 10 related papers. Consider them for comparative context: