Why the study?
Does an everolimus-eluting bioresorbable vascular scaffold prevent target-lesion failure at 1 year in patients with noncomplex obstructive coronary artery disease compared to an everolimus-eluting cobalt-chromium stent?
Does an everolimus-eluting bioresorbable vascular scaffold prevent target-lesion failure at 1 year in patients with noncomplex obstructive coronary artery disease compared to an everolimus-eluting cobalt-chromium stent?
Answers are grounded in this paper and cite their sources.
Captured external expert commentary on this paper, strongest first. Original sources are linked where available.
“As a clinician, I really want to see that long-term data before switching my practice to BVS because we have been burnt in the past before, switching to newer devices without longer-term data.”
Everolimus-eluting bioresorbable vascular scaffolds demonstrated noninferiority to everolimus-eluting cobalt-chromium stents for target-lesion failure at 1 year in noncomplex obstructive CAD.
In this large-scale, randomized trial, treatment of noncomplex obstructive coronary artery disease with an everolimus-eluting bioresorbable vascular scaffold, as compared with an everolimus-eluting cobalt-chromium stent, was within the prespecified margin for noninferiority with respect to target-lesion failure at 1 year. (Funded by Abbott Vascular; ABSORB III ClinicalTrials.gov number, NCT01751906.).
Journal, society, and media accounts. Useful signal, not independent expert judgment.
No takes yet. Share an insight, caveat, or question.
Ellis et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: