Why the study?
Does the use of polymer-free biolimus-eluting stents provide a favorable safety and efficacy profile in all-comer patients irrespective of high bleeding risk status?
Does the use of polymer-free biolimus-eluting stents provide a favorable safety and efficacy profile in all-comer patients irrespective of high bleeding risk status?
Polymer-free biolimus-eluting stents demonstrate a favorable safety and efficacy profile in a real-world all-comer population, supporting the need for future randomized trials against new-generation DES.
Answers are grounded in this paper and cite their sources.
Supports PF-BES consideration in real-world all-comers; leaves open direct RCTs versus new-generation DES.
This is the first study providing clinical evidence on the use of PF-BES in all-comer patients irrespective of HBR status. Our findings suggest that PF-BES has a favourable safety and efficacy profile in a real-world clinical setting. Further investigation in randomised clinical trials against new-generation DES is warranted.
No takes yet. Share an insight, caveat, or question.
Sardella et al. (2018) studied this question.