December 26, 2007New England Journal of Medicine961 citationsOpen Access

Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy

View Full Paper
VRVivek Y. ReddyMRMatthew R. ReynoldsPNPetr Neužil

Key Points

  • To evaluate the effectiveness of prophylactic catheter ablation in reducing ICD therapy for patients with a history of myocardial infarction.
  • Randomized trial design

Structured PICO

Does prophylactic substrate-based catheter ablation reduce the incidence of ICD therapy in patients with a history of myocardial infarction who received ICDs for the secondary prevention of sudden death?

P
Population
Patients with a history of myocardial infarction who received ICDs for the secondary prevention of sudden death
I
Intervention
Prophylactic substrate-based catheter ablation
O
Outcome
Incidence of ICD therapy

Prophylactic substrate-based catheter ablation reduces the incidence of ICD therapy in patients with prior MI receiving ICDs for secondary prevention.

Abstract

In this randomized trial, prophylactic substrate-based catheter ablation reduced the incidence of ICD therapy in patients with a history of myocardial infarction who received ICDs for the secondary prevention of sudden death. (Current Controlled Trials number, ISRCTN62488166 controlled-trials.com.).

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Reddy et al. (2007) studied this question.

synapsesocial.com/papers/69dea73b4838c5c0bab0c82bhttps://doi.org/10.1056/nejmoa065457