The study was conducted to evaluate correlations between different types of femoro-acetabular impingement and the ratio of acetabular volume to femoral head volume on MR arthrography, and to assess 2D versus 3D measurements for identifying impingement types.
Does 3D measurement of acetabular to femoral head volume ratio improve accuracy in classifying femoro-acetabular impingement compared to 2D measurements?
Does 3D measurement of acetabular to femoral head volume ratio improve accuracy in classifying femoro-acetabular impingement compared to 2D measurements?
3D measurements of the acetabular to femoral head volume ratio on MR arthrography are more accurate than 2D measurements for classifying femoro-acetabular impingement types.
This is the authors' abstract. We don't add key points for this paper.
Purpose (1) To investigate correlations between different types of FAI and the ratio of acetabular volume (AV) to femoral head volume (FV) on MR arthrography. (2) To assess 2D/3D measurements in identifying different types of FAI by means of cut-off values of AV/FV ratio (AFR). Materials and methods Alpha angle, cranial acetabular version, acetabular depth, lateral center edge angle, AV, and FV of 52 hip MR arthrography were measured. ANOVA test correlated different types of FAI with AFR. ROC curves classified FAI by cut-off values of AFR. Accuracy of 2D/3D measurements was calculated. Results ANOVA test showed a significant difference of AFR ( p value < 0.001) among the three types of FAI. The mean values of AFR were 0.64, 0.74, and 0.89 in cam, mixed, and pincer types, respectively. Cut-off values of AFR were 0.70 to distinguish cam types from mixed and pincer types, and 0.79 to distinguish pincer types from cam and mixed types. Cut-off values identified 100%, 73.9%, and 55.6% of pincer, cam, and mixed types. 2D and 3D classifications of FAI showed accuracy of 40.4% and 73.0%. Conclusions 3D measurements were clearly more accurate than 2D measurements. Distinct cut-off values of AFR discriminated cam types from pincer types and identified pincer types in all cases. Cam and mixed types were not accurately recognized.
Answers are grounded in this paper and cite their sources.
May support 3D over 2D FAI classification on MR arthrography; leaves open prospective validation before practice change.