Why the study?
Does the Shannon entropy method accurately detect atrial fibrillation using RR interval features?
Does the Shannon entropy method accurately detect atrial fibrillation using RR interval features?
The Shannon entropy method demonstrates good diagnostic performance for detecting atrial fibrillation from RR intervals.
Answers are grounded in this paper and cite their sources.
Should not yet change AF detection practice; hypothesis-generating for entropy-based RR algorithms.
Atrial Fibrillation is one of heart disease, that common characterized by irregularity heart beat. Atrial fibrillation leads to severe complications such as cardiac failure with the subsequent risk of a stroke. A method to detect atrial fibrillation is needed to prevent a risk of atrial fibrillation. This research uses data from physionet in atrial fibrillation database category. The performance of Shannon entropy has the highest accuracy if a threshold is 0.5 with accuracy 89.79%, sensitivity 91.04% and specificity 89.01%. Based on the result we get a conclusion, the ability of Shannon entropy to detect atrial fibrillation is good.
No takes yet. Share an insight, caveat, or question.
Afdala et al. (2017) studied this question.