Key result
Using normalized elastance at ejection onset minimizes error sensitivity in single-beat ESPVR slope estimation.
Single-beat estimation of ESPVR is an inverse problem requiring physiologically consistent auxiliary relations, such as normalized elastance at the onset of ejection, to achieve mathematical closure.
Answers are grounded in this paper and cite their sources.
Requires caution interpreting single-beat Ees clinically; challenges its structural foundations in research.
Single-beat (SB) approaches for estimating the end-systolic pressure-volume relationship (ESPVR) from a single pressure-volume (P-V) loop are widely used in experimental and clinical research, yet their structural foundations remain insufficiently formalized. ESPVR is a phenomenological construct defined from multi-beat (MB) measurements across varying loading conditions, and its SB estimation therefore constitutes an inverse problem. We show that SB estimation of the ESPVR slope (Ees) is intrinsically underdetermined, as a single P-V loop provides fewer independent constraints than unknown parameters. Consequently, any SB method requires auxiliary information to achieve mathematical closure. Using nine high-fidelity P-V loops obtained during vena cava occlusion in a porcine model as a demonstrator dataset, we quantify (i) the sensitivity of the MB-derived Ees,MB to the selection of the P-V loop subset, and (ii) the sensitivity of Ees to representative classes of auxiliary information. The analysis reveals that auxiliary information based solely on population-averaged normalized elastance curves is structurally inconsistent with the MB reference definition. Among the examined candidates, the normalized elastance at the onset of ejection (EN,dia) exhibits the most favorable structural properties, combining low sensitivity of Ees to estimation errors with a strong empirical association captured by regression modeling. By reframing SB estimation of ESPVR as a structural identifiability problem rather than a purely numerical task, this study establishes criteria for physiologically consistent auxiliary relations and highlights the necessity of large, standardized MB databases for future data-driven SB methodologies. .
No takes yet. Share an insight, caveat, or question.
Lulić et al. (2026) studied ventricular end-systolic pressure-volume relationship estimation (n=9). Single-beat estimation of ESPVR vs. Multi-beat measurements was evaluated on Sensitivity of Ees to the selection of the P-V loop subset and auxiliary information. Single-beat estimation of the ESPVR slope is intrinsically underdetermined, but using normalized elastance at ejection onset provides favorable structural properties and low error sensitivity.
Synapse has enriched 10 related papers. Consider them for comparative context: