Key result
Physiology-guided strategy for high-risk coronary obstruction during TAVR potentially avoids prophylactic chimney stenting.
Why the study?
Coronary artery obstruction is a rare but devastating complication of TAVR, and prophylactic chimney stenting carries long-term risks.
Does physiological assessment using FFR prevent unnecessary chimney stenting in a patient with high-risk coronary obstruction anatomy during TAVR?
Case Report (n=1)
Does physiological assessment using FFR prevent unnecessary chimney stenting in a patient with high-risk coronary obstruction anatomy during TAVR?
Answers are grounded in this paper and cite their sources.
Dynamic FFR monitoring during TAVR can differentiate anatomical proximity from true functional ischemia, safely avoiding unnecessary chimney stenting in high-risk anatomy.
BACKGROUND: Coronary artery obstruction is a rare but devastating complication of transcatheter aortic valve replacement (TAVR). Prophylactic chimney stenting is a bailout strategy but carries long-term risks. CASE SUMMARY: A 72-year-old woman with severe aortic stenosis and high-risk coronary artery obstruction anatomy (low left coronary ostium height of 9.1 mm, redundant calcified leaflet) underwent TAVR. Angiography after valve deployment showed ambiguous left coronary leaflet displacement with delayed contrast clearance. However, immediate and dynamic fractional flow reserve (FFR) assessments consistently remained above the ischemic threshold (>0.80) despite aggressive balloon postdilations. Consequently, chimney stenting was safely deferred. The patient was asymptomatic at the 3-month follow-up. DISCUSSION: Relying solely on anatomical predictors may lead to overtreatment. Physiological assessment using FFR effectively defines the functional significance of anatomical proximity, safely avoiding unnecessary permanent implants. TAKE-HOME MESSAGE: Dynamic FFR monitoring differentiates anatomical proximity from true functional ischemia during TAVR, safely guiding the avoidance of unnecessary chimney stenting.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2026) conducted a case report in Severe aortic stenosis and high-risk coronary artery obstruction anatomy (n=1). Physiology-guided strategy using dynamic fractional flow reserve (FFR) was evaluated on Ischemic threshold (FFR >0.80). Dynamic FFR monitoring during TAVR demonstrated FFR >0.80 despite high-risk anatomy, safely guiding the avoidance of unnecessary chimney stenting.
Synapse has enriched 10 related papers. Consider them for comparative context: