A nonlinear equivalent circuit model for the GaAs FET has been developed based upon the small-signal device model and separate current measurements, including drain-gate avalanche current data. The harmonic-balance technique is used to develop the FET RF load-pull characteristics in an amplifier configuration under large-signal operation. Computed and experimental load-pull results show good agreement.
No takes yet. Share an insight, caveat, or question.
Curtice et al. (1985) studied this question.