Key result
Circular-array PFA for PVI linked to acute blood pressure drops, predominantly during the first treatment.
Why the study?
Data regarding acute blood pressure drops during pulsed-field ablation for pulmonary vein isolation are limited.
What is the incidence and what are the risk factors for acute blood pressure drops during circular-array pulsed-field ablation for pulmonary vein isolation?
Observational (n=50)
What is the incidence and what are the risk factors for acute blood pressure drops during circular-array pulsed-field ablation for pulmonary vein isolation?
Acute blood pressure drops are common during circular-array pulsed-field ablation for pulmonary vein isolation, occurring predominantly during the first pulmonary vein treatment.
Answers are grounded in this paper and cite their sources.
May warrant intraprocedural BP monitoring during first-vein pulsed-field ablation; leaves open mechanistic and mitigation studies.
BACKGROUND: Data regarding acute blood pressure (BP) drops during pulsed-field ablation (PFA) for pulmonary vein isolation (PVI) are limited. OBJECTIVE: This study aimed to determine the incidence and risk factors of acute BP drops during PFA-PVI. METHODS: We retrospectively analyzed 50 consecutive patients who underwent PFA-PVI using a circular-array system (PulseSelect, Medtronic Inc). 4 predefined sequencing protocols were compared and categorized according to the first targeted pulmonary vein (PV). Systolic BP was recorded immediately after each application. A BP drop was defined as a >40 mm Hg decrease or an absolute value of <60 mm Hg; a severe BP drop was defined as one requiring intervention. RESULTS: Among 1797 applications, BP drops occurred in 205 applications (11%), and 38 of 50 patients (76%) experienced at least 1 episode. Severe BP drops occurred in 30 applications (2%) in 16 patients (32%); 53% clustered in the left superior PV-first protocol. Coughing was significantly more frequent in applications with BP drops than in those without (54% vs 26%; P < .001). Across all protocols, systolic BP decreased after each application, with attenuation in magnitude as the sequence progressed (P < .001). In multivariable models, earlier application order and distal-segment applications were independently associated with BP drops, whereas severe BP drops were independently associated with left PV targeting. In sequence-stratified models, the first PV treated (applications 1-9) carried the highest risk, with a stepwise decline in risk across subsequent blocks. CONCLUSION: Acute BP drops are common during circular-array PFA-PVI and occur predominantly during the first PV treatment.
No takes yet. Share an insight, caveat, or question.
Hashimoto et al. (2026) conducted an observational in Pulmonary vein isolation (n=50). Circular-array pulsed-field ablation was evaluated on Acute blood pressure drop (>40 mm Hg decrease or absolute value <60 mm Hg). Acute blood pressure drops occurred in 76% of patients during circular-array pulsed-field ablation for pulmonary vein isolation, predominantly during the first pulmonary vein treatment.