Study monitors lithium plating in graphite pouch cells, suggesting new insights for battery safety.
Real-time detection of lithium plating under extreme conditions is critical for battery safety. Here, we use embedded fiber Bragg grating (FBG) sensors to achieve real-time monitoring of mechanical strain evolution in operating graphite pouch cells. At ultralow temperatures (–20 and –30 °C), we observe an anomalous suppression in differential strain (dε/dQ) during late-stage charging . Specifically, the strain generation rate is severely constrained, dropping to approximately 0.1 με/mAh at high state-of-charge (SOC)—a stark contrast to the normal intercalation baseline of ~0.3 με/mAh observed under milder, non-plating conditions. Through synchronized electrochemical analysis and post-mortem characterization, we show that this mechanical anomaly reflects a fundamental shift in plating behavior: at cryogenic temperatures, internal mechanical constraints imposed by prior plating and SEI densification suppress further expansion, altering the progression of lithium deposition. The real-time strain signals also reveal a dynamic competition between SEI fracture-repair cycles and lithium re-plating, providing insight into coupled degradation mechanisms governing battery failure. This work establishes an in-situ diagnostic tool for battery failure and offers new mechanistic understanding of lithium plating under extreme conditions.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: