Why the study?
Are frequent premature atrial contractions associated with an increased risk of future atrial fibrillation, brain ischaemia, and all-cause mortality in patients without a history of AF?
Are frequent premature atrial contractions associated with an increased risk of future atrial fibrillation, brain ischaemia, and all-cause mortality in patients without a history of AF?
Frequent premature atrial contractions detected on 24-48 hour Holter monitoring are significantly associated with an increased risk of incident atrial fibrillation, first stroke, and all-cause mortality in older patients without prior AF.
Answers are grounded in this paper and cite their sources.
May support enhanced AF monitoring in frequent PAC patients; extends observational meta-analyses but leaves causal effects and interventions open.
AIMS: Premature atrial contractions (PACs) are a common cardiac phenomenon, traditionally considered to be of little clinical significance. Recent studies, however, suggest that PACs are associated with atrial fibrillation (AF), as well as ischaemic stroke, transient ischaemic attack, and mortality. This systematic review aims to investigate the association between PACs on standard electrocardiogram (ECG) as well as PAC-count on Holter monitor and future detection of AF, brain ischaemia, and all-cause mortality in patients without a history of AF. METHODS AND RESULTS: We searched PubMed, Embase (OVID), and Cochrane Database of Systematic Reviews from inception through 11 April 2018 and performed a systematic review and meta-analysis. We assessed risk of bias using a modified Quality In Prognosis Studies tool. The primary expression of associations in meta-analysis was the unadjusted hazard ratio (HR) using a random effects model. We identified 33 eligible studies including 198 876 patients from Western and East Asian populations with mean age ranging 52-76 years. Frequent PACs on 24-48 h Holter was associated with AF [HR 2.96, 95% confidence interval (CI) 2.33-3.76; 15 cohorts, n = 16 613], first stroke (HR 2.54, 95% CI 1.68-3.83; 3 cohorts, n = 1468), and all-cause mortality (HR 2.14, 95% CI 1.94-2.37; 6 cohorts, n = 7571). There was insufficient evidence to conclude that presence of ≥1 PAC on standard 12-lead ECG is associated with future AF detection. CONCLUSION: In older patients without a history of AF, frequent PACs on 24-48 h Holter are significantly associated with AF, first stroke, and mortality.
No takes yet. Share an insight, caveat, or question.
Himmelreich et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: