Answers are grounded in this paper and cite their sources.
Parametric analysis reveals mass-flow rates impact thermal conductivity in a graphene-water nanofluid system.
This work presents a case study on a concentric counter‐flow tubular heat exchanger where a graphene‐sheet/water nanofluid flows in the inner tube and a polymer coolant (PEG‐400) flow in the annulus. A property‐consistent modelling framework is developed: particle shape anisotropy is captured via the Hamilton–Crosser (HC) model with shape factor inferred from thindisk sphericity; nanofluid viscosity follows the Krieger–Dougherty law with platelet intrinsic viscosity; internal convection uses Sieder–Tate (laminar) and Dittus–Boelter (turbulent) correlations; overall performance is computed via the ε –NTU method with full wall and fouling resistances. A parametric study varies nanofluid inlet temperature (50–70°C), graphene volume fraction (0–3 vol.%), polymer inlet temperature (20–30°C), and mass‐flow rates (nanofluid = 0.05–0.20 kg/s; polymer = 0.10–0.30 kg/s). Results show that, for the chosen geometry ( L = 6 m; inner tube: 10 mm inner diameter and 12 mm outer diameter; outer tube: 25 mm inner diameter) and fouling levels, mass‐flow control provides the strongest leverage on heat duty, while small graphene loadings produce modest gains.
No takes yet. Share an insight, caveat, or question.
Abdulaal Zuhayr Al Khazaal (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: