Why the study?
Thrombus aspiration during primary PCI in STEMI patients with high thrombus burden remains an important consideration, prompting evaluation of the impact of aspiration catheter size on thrombus removal and the slow-flow/no-reflow phenomenon.
Does a 7-French aspiration catheter reduce slow-flow/no-reflow compared to a 6-French catheter in STEMI patients with high thrombus burden undergoing primary PCI?
Does a 7-French aspiration catheter reduce slow-flow/no-reflow compared to a 6-French catheter in STEMI patients with high thrombus burden undergoing primary PCI?
Using a larger 7-French aspiration catheter during primary PCI for STEMI with high thrombus burden significantly improves final TIMI flow and reduces the incidence of slow-flow/no-reflow compared to a standard 6-French catheter.
Answers are grounded in this paper and cite their sources.
May reduce no-reflow with 7-French catheters in high-thrombus STEMI PCI; leaves open randomized confirmation before practice change.
BACKGROUND: Thrombus aspiration during primary percutaneous coronary intervention (PCI) in ST-elevation myocardial infarction (STEMI) patients with a high thrombus burden remains an important clinical consideration. This study aimed to evaluate the impact of aspiration catheter size on thrombus removal and the slow-flow/no-reflow phenomenon. METHODS: This retrospective study included 208 STEMI patients presenting within 12 h of symptom onset with high thrombus burden. All underwent primary PCI with thrombus aspiration. Patients were divided based on catheter size: 7-French ( n = 85) and 6-French ( n = 123). Clinical characteristics, procedural outcomes, and angiographic results were compared. Multivariate logistic regression identified independent predictors of slow-flow/no-reflow. RESULTS: Patients treated with a 7-French catheter had a lower incidence of slow-flow/no-reflow after stent deployment (14.0 vs. 36.6%; P < 0.001) and postdilatation (25.0 vs. 55.2%; P = 0.003). Final thrombolysis in myocardial infarction 3 flow was more frequently achieved in the 7-French group (100 vs. 90.2%; P = 0.032). History of stroke or transient ischemic attack [odds ratio (OR): 5.16; P = 0.021] and ischemic time greater than 330 min (OR: 2.13; P = 0.032) were predictors of no-reflow, while use of a 7-French catheter was protective (OR: 0.26; P < 0.001). CONCLUSION: In STEMI patients with high thrombus burden, using a 7-French aspiration catheter was associated with higher procedural success and lower incidence of slow-flow/no-reflow. Larger-caliber catheters may offer a clinical advantage in selected patients undergoing primary PCI.
No takes yet. Share an insight, caveat, or question.
Chaturonrutsamee et al. (2025) studied this question.