Why the study?
The accuracy of resting full-cycle ratio (RFR) in detecting hemodynamically significant coronary artery stenosis compared to fractional flow reserve (FFR) needed evaluation.
Does resting full-cycle ratio (RFR) accurately detect hemodynamically significant coronary artery stenosis compared to fractional flow reserve (FFR) in patients with coronary lesions?
Does resting full-cycle ratio (RFR) accurately detect hemodynamically significant coronary artery stenosis compared to fractional flow reserve (FFR) in patients with coronary lesions?
RFR demonstrates good diagnostic accuracy for detecting coronary ischemic lesions and may serve as an effective non-hyperemic alternative to FFR.
Answers are grounded in this paper and cite their sources.
RFR supports non-hyperemic ischemia assessment in practice; extends meta-analytic evidence for its diagnostic role versus FFR.
BACKGROUND: The resting full-cycle ratio (RFR), a new non-congestive resting index, is commonly used for physiological evaluations of coronary arteries. AIMS: This study aims to evaluate the accuracy of RFR in detecting coronary artery stenosis with hemodynamic significance using fractional flow reserve (FFR) as the reference standard. METHODS: Using 'RFR, resting full-cycle ratio' as the search term, we searched PubMed, Embase, Cochrane Library, and Web of Science databases, screening the literature according to the inclusion and exclusion criteria. By applying FFR ≤ 0.80 and RFR ≤ 0.89 as the diagnostic criteria for ischaemia, we analysed the synthetic sensitivity, specificity, and corresponding 95% confidence intervals, then synthesised the summary receiver operating characteristic curve (SROC). RESULTS: Three studies were included in this meta-analysis, comprising 1,084 patients with 1,312 lesions. When we used FFR ≤ 0.80 as the reference standard, the synthesised sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative likelihood ratio (LR-) of RFR in the diagnosis of coronary ischaemia were 73%, 81%, 67%, 85%, 3.95, and 0.33, respectively. Besides, the area under the curve (AUC) was 0.8276. CONCLUSION: Using FFR as the reference standard, RFR has good diagnostic accuracy in detecting coronary ischaemic lesions and may be an effective alternative to FFR in the future, to some extent.
No takes yet. Share an insight, caveat, or question.
Luo et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: