Why the study?
A cardiac CT-based MAC scoring system systematically grades MAC severity, but its correlation with 3D-TEE remains unclear.
Does 3D-TEE MAC scoring correlate with CT MAC scoring and hemodynamic parameters in patients with mitral annular calcification undergoing TMVR screening?
Does 3D-TEE MAC scoring correlate with CT MAC scoring and hemodynamic parameters in patients with mitral annular calcification undergoing TMVR screening?
3D-TEE provides functionally relevant assessment of mitral annular calcification that correlates better with mitral stenosis severity than CT scoring, making it a useful adjunct for TMVR evaluation.
Answers are grounded in this paper and cite their sources.
3D-TEE may better inform mitral stenosis severity than CT in TMVR screening; leaves open its clinical adoption pending validation.
BACKGROUND: A cardiac computed tomography (CT)-based mitral annular calcification (MAC) scoring system systematically grades MAC severity, but its correlation with three-dimensional transesophageal echocardiography (3D-TEE) remains unclear. OBJECTIVES: The authors aimed to compare MAC severity assessment by 3D-TEE vs CT and evaluate their associations with hemodynamic parameters indicative of mitral valve disease. METHODS: We analyzed patients with MAC enrolled in the MITRAL (Mitral Implantation of TRAnscathether vaLves) II trial (NCT04408430) across 13 centers undergoing transcatheter mitral valve replacement screening. Core laboratories assessed MAC severity using 3D-TEE and CT. Correlation and agreement were assessed via Spearman and intraclass correlation coefficients. Hemodynamic parameters of mitral stenosis (MS) and regurgitation were obtained from two-dimensional transthoracic echocardiography (2D-TTE) and 3D-TEE. Linear regression evaluated associations with MAC scores. RESULTS: decrease in 2D-TTE mitral valve area, and an increase in mean diastolic pressure gradient (1 mm Hg by 3D-TEE; 0.96 mm Hg by 2D-TTE). 3D-TEE MAC scores showed no significant correlation with regurgitation parameters. CT-MAC scores showed weak, nonsignificant correlations with both MS and mitral regurgitation. CONCLUSIONS: 3D-TEE provides complementary and functionally relevant MAC assessment, correlating with MS severity. It may serve as a useful adjunct to CT in transcatheter mitral valve replacement evaluation, especially when contrast imaging is limited.
No takes yet. Share an insight, caveat, or question.
Analuisa et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: