Key result
CMR variables strongly outperform clinical variables in discriminating high from low AF burden.
Why the study?
Atrial fibrillation burden has prognostic implications, but the ability of clinical and cardiac imaging variables to stratify between high and low burden required assessment.
Do cardiac magnetic resonance imaging variables improve the discrimination of high versus low atrial fibrillation burden compared to clinical variables?
Observational (n=170)
Yes
Do cardiac magnetic resonance imaging variables improve the discrimination of high versus low atrial fibrillation burden compared to clinical variables?
Cardiac magnetic resonance imaging variables strongly outperform standard clinical variables in estimating atrial fibrillation burden.
Answers are grounded in this paper and cite their sources.
Exercise caution linking LA volume to AF burden; leaves open causality and clinical utility pending larger prospective validation.
Background Recent studies indicate that atrial fibrillation (AF) burden has prognostic implications. Objective We aimed to assess the ability of clinical and cardiac imaging variables to stratify between high and low AF burden. Method Data from the prospective, multicenter Swiss-AF Burden study were analyzed. Patients underwent a 7-day Holter electrocardiogram and native cardiac magnetic resonance imaging. AF burden, defined as the percentage of time in AF during the 7-day Holter electrocardiogram, was dichotomized into low (<10%) or high (≥10%). Logistic regression models were built, and discriminative performance was evaluated by comparing the area under the curve (AUC). Results A total of 170 patients were enrolled (median age 72 years; 18% female); 26% (n = 44) had high AF burden. Variables selected for the clinical model were age (odds ratio 1.09; 95% confidence interval 0.40–2.74), male sex (1.05; 1.00–1.11), and body mass index (1.14; 1.06–1.24). The imaging model included left atrial maximal volume index (1.04; 1.01–1.06), left ventricular end-diastolic volume index (0.93; 0.90–0.96), right atrial fractional area change (0.94; 0.89–0.98), and left ventricular ejection fraction (0.87; 0.81–0.94). The AUCs for the clinical and imaging models were 0.67 (0.58–0.77) and 0.91 (0.84–0.98), respectively. Combining both models yielded an AUC of 0.92 (0.86–0.99), with no substantial improvement over the imaging model alone. Conclusion Cardiac imaging variables clearly outperformed clinical variables in their ability to stratify between high and low AF burden, suggesting their potential as a tool for estimating AF burden.
No takes yet. Share an insight, caveat, or question.
Gasser et al. (2026) conducted an observational in Atrial fibrillation (n=170). Cardiac magnetic resonance imaging variables vs. Clinical variables was evaluated on Discrimination between high (≥10%) and low (<10%) atrial fibrillation burden (AUC, 95% CI 0.84-0.98). Cardiac magnetic resonance imaging variables outperformed clinical variables in discriminating high from low atrial fibrillation burden.
Synapse has enriched 10 related papers. Consider them for comparative context: