Why the study?
What are the determinants of survival, functional status, and change in left ventricular ejection fraction in patients with low-flow, low-gradient aortic stenosis?
What are the determinants of survival, functional status, and change in left ventricular ejection fraction in patients with low-flow, low-gradient aortic stenosis?
Impaired functional capacity, more severe valve stenosis by projected AVA, and reduced peak stress LVEF are significant predictors of poor outcomes in low-flow, low-gradient aortic stenosis.
These predictors may refine risk stratification in low-flow low-gradient AS; hypothesis-generating, requires prospective validation before guiding decisions.
BACKGROUND: Patients with low-flow, low-gradient aortic stenosis have a poor prognosis with conservative therapy but a high operative mortality if treated surgically. Recently, we proposed a new index of aortic stenosis severity derived from dobutamine stress echocardiography, the projected aortic valve area at a normal transvalvular flow rate, as superior to other conventional indices to differentiate true-severe from pseudosevere aortic stenosis. The objective of this study was to identify the determinants of survival, functional status, and change in left ventricular ejection fraction during follow-up of patients with low-flow, low-gradient aortic stenosis. METHODS AND RESULTS: One hundred one patients with low-flow, low-gradient aortic stenosis (aortic valve area </=1.2 cm(2), left ventricular ejection fraction </=40%, and mean gradient </=40 mm Hg) underwent dobutamine stress echocardiography and an assessment of functional capacity using the Duke Activity Status Index. A subset of 72 patients also underwent a 6-minute walk test. Overall survival was 70+/-5% at 1 year and 57+/-6% at 3 years. After adjusting for age, gender, and the type of treatment (aortic valve replacement versus no aortic valve replacement), significant predictors of mortality during follow-up were a Duke Activity Status Index </=20 (P=0.0005) or 6-minute walk test distance </=320 m (P<0.0001, in the subset of 72 patients), projected aortic valve area at a normal transvalvular flow rate </=1.2 cm(2) (P=0.03), and peak dobutamine stress echocardiography left ventricular ejection fraction </=35% (P=0.03). More severe stenosis, defined as projected aortic valve area </=1.2 cm(2), was a predictor of mortality only in the no aortic valve replacement group. The Duke Activity Status Index, 6-minute walk test, and left ventricular ejection fraction improved significantly during follow-up in the aortic valve replacement group, but remained unchanged or decreased in the no aortic valve replacement group. CONCLUSIONS: In patients with low-flow, low-gradient aortic stenosis, the most significant risk factors for poor outcome were (1) impaired functional capacity as measured by Duke Activity Status Index or 6-minute walk test distance; (2) more severe valve stenosis as measured by projected aortic valve area at a normal transvalvular flow rate; and (3) reduced peak stress left ventricular ejection fraction, a composite measure accounting for both resting left ventricular function and contractile reserve.
No takes yet. Share an insight, caveat, or question.
Clavel et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More from Circulation